Single Resolver (PG) Feedback - PM Motor. This option provides velocity and direction feedback from a resolver. This is used for motor feedback in “Closed Loop Vector for PM Motor” control mode.
Signal levels:
7 Vac rms: transformer ratio of 0.5 ±5% maximum input
100mA rms
Maximum input frequency: 10kHz
Maximum RPM: 24000
Note: It is required that the A1000 drive contain 1017 software or
later; please consult your Yaskawa representative to ensure proper
operation.
Mounts at option connector CN5-C